Alert Test Commands; Email Test Command; Alert Data Definitions - Dell Remote Access Controller 4 Firmware Version 1.30 User Manual

Remote access controller 4 firmware version 1.30
Table of Contents

Advertisement

Table B-5. Alert Filter Property Group and Object IDs (continued)
GroupID
cfgOobSnmp
cfgTraps
cfgTraps
cfgTraps
cfgTraps
cfgTraps

Alert Test Commands

You can test alerts using test commands. The racadm command has subcommands that test the
different types of alert interfaces. These object ID sets cause the firmware to execute the
subcommand with the option that indicates the test alert type to test. The test message is preset
in properties for each test alert type. The types of alerts are email and trap.
The following subsection describes the command interfaces and the operation of the
subcommand for each option.

Email Test Command

Synopsis
racadm testemail -i < index >
racadm testemail -u < username >

Alert Data Definitions

The email alert contains the following information: message (including test message, if a paging
test), event description, date, time, severity, system ID, model, BIOS version, asset tag, service
tag, managed system name, operating system name, and BMC version. The following is an
example test email (fields shown are examples only and may not reflect actual observed output
for your environment):
Subject: Alert from Dell Remote Access Card: 10.35.10.108
Message: TEST PAGE
Event: Email paging test to user 1
Date: 06-jun-2004
Time: 00:01:37
Severity: Info/Normal
Object ID
cfgOobSnmpTrapsEnable
cfgTrapsDestIpAddr
cfgTrapsEnable
cfgTrapsSnmpCommunity
cfgTrapsFilterRacEventMask
cfgTrapsFilterSysEventMask
DRAC 4 Property Database Group and Object Definitions
Object Default Value
TRUE
0.0.0.0
FALSE
""
0x777777
0x777777
223

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Drac 4

Table of Contents