• Direct connection between the Control Board and System Controllers ("Home Run" Type Wiring)
In this type of installation there is one control cable directly connecting each System Controller to one Control Board port.
Refer to the connections and controller settings shown below.
Termination and Controller Unit Number Setting
Termination
Switch
Controller 1
ON
Controller 2
ON
Controller 3
ON
Controller 4
ON
Controller 5
ON
Controller 6
ON
Controller 7
ON
Controller 8
ON
Matrix Switcher WJ-SX550A
Control Board
CONTROL
DATA 1
DATA 2
DATA 3
DATA 4
DATA 5
DATA 6
DATA 7
DATA 8
TEST 1
TEST 2
Controller
Unit Number
Any Number 1-8
Any Number 1-8
Any Number 1-8
Any Number 1-8
Any Number 1-8
Any Number 1-8
Any Number 1-8
Any Number 1-8
-57-
DATA
IN
OUT
TERM
ON
OFF
DATA
IN
OUT
TERM
ON
OFF
DATA
IN
OUT
TERM
ON
OFF
DATA
IN
OUT
TERM
ON
OFF
DATA
IN
OUT
TERM
ON
OFF
DATA
IN
OUT
TERM
ON
OFF
DATA
IN
OUT
TERM
ON
OFF
DATA
IN
OUT
TERM
ON
OFF
Home Run Connections
Note: Do not use the "0" or "9" controller unit numbers.
CONTROLLER
UNIT NO.
Controller 1
1-8
0
5
CONTROLLER
UNIT NO.
Controller 2
1-8
0
5
CONTROLLER
UNIT NO.
Controller 3
1-8
0
5
CONTROLLER
UNIT NO.
1-8
Controller 4
0
5
CONTROLLER
UNIT NO.
1-8
Controller 5
0
5
CONTROLLER
UNIT NO.
1-8
Controller 6
0
5
CONTROLLER
UNIT NO.
1-8
Controller 7
0
5
CONTROLLER
UNIT NO.
1-8
Controller 8
0
5
4