Portable Station-Extension Settings [4-2-1] - Panasonic KX-TDA100 Features Manual

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA100:
Table of Contents

Advertisement

Network BLF Data to NDSS Key of Other PBX - Other PBX (Network PBX
ID=1)
Selects whether status data is transmitted over the network for the selected extension. This setting can only
be changed from ON to OFF, to cancel data transmission.
Default
OFF
Value Range
OFF, ON
Programming Guide References
4.15.1 TIE Table [9-1]
Feature Guide References
1.27.2.3 Network Direct Station Selection (NDSS) (KX-TDA0920 required)
4.10.9 Portable Station—Extension Settings [4-2-1]
For each Portable Station (PS), various extension settings can be assigned. A maximum of 128 PSs can be
programmed.
It is possible to assign a set of CLIP numbers automatically. Click CLIP Generate.
Main
Extension Number
Indicates the extension number of the PS (reference only).
Default
Not stored.
Value Range
Max. 4 digits (consisting of 0–9)
Programming Guide References
4.7.14 Portable Station [1-2]
Feature Guide References
None
Extension Name
Specifies the name of the PS. As for the available characters, refer to the character code table described in
section 3.2.1 Installing and Starting KX-TDA Maintenance Console.
4.10 Extension [4]