Table 19
controllers properties (continued)
Name
Type
dash-level
string
fru-shortname
string
mfg-date
string
mfg-date-
string
numeric
mfg-location
string
mfg-vendor-id
string
health
string
health-numeric
string
health-reason
string
health-
string
recommendation
position
string
position-
string
numeric
phy-isolation
string
phy-isolation-
string
numeric
redundancy-mode
string
Description
FRU template revision number.
FRU short description.
Date and time, in the format year-month-day hour:minutes:seconds
(UTC), when the controller's PCBA was programmed.
Unformatted mfg-date value.
City, state/province, and country where the FRU was manufactured.
JEDEC ID of the FRU manufacturer.
OK
Fault
Unknown
Numeric equivalents for health values.
0: OK
2: Fault
3: Unknown
If Health is not OK, the reason for the health state.
If Health is not OK, the recommended actions to take to resolve the health issue.
Position of the controller in the enclosure.
Top: The controller is in the top slot.
Bottom: The controller is in the bottom slot.
Numeric equivalents for position values.
0: Top
1: Bottom
Shows whether the automatic disabling of SAS expander PHYs having high error
counts is enabled or disabled for this controller.
Enabled: PHY fault isolation is enabled. This is the default.
Disabled: PHY fault isolation is disabled.
Numeric equivalents for phy-isolation values.
0: Enabled
1: Disabled
The system's operating mode, also called the cache redundancy mode.
Active-Active ULP: Both controllers are active using ULP (Unified LUN
Presentation). Data for volumes configured to use write-back cache is
automatically mirrored between the two controllers to provide fault
tolerance.
Single Controller: The enclosure contains a single controller.
Single Controller: The enclosure contains a single controller.
Fail Over: Operation has failed over to one controller because its partner
is not operational. The system has lost redundancy.
Down: Both controllers are not operational.