Table 24
drive-parameters properties (continued)
Name
disk-dsd-delay
disk-dsd-
enable-pool-
numeric
Example
# show disk-parameters
...
<OBJECT basetype="drive-parameters" name="drive-parameters" oid="1" format="pairs">
<PROPERTY name="smart" type="string">Enabled</PROPERTY>
<PROPERTY name="smart-numeric" type="string">1</PROPERTY>
<PROPERTY name="drive-write-back-cache" type="string">Disabled</PROPERTY>
<PROPERTY name="drive-write-back-cache-numeric" type="string">2</PROPERTY>
<PROPERTY name="drive-timeout-retry-max" type="uint8">3</PROPERTY>
<PROPERTY name="drive-attempt-timeout" type="uint8">8</PROPERTY>
<PROPERTY name="drive-overall-timeout" type="uint8">105</PROPERTY>
<PROPERTY name="disk-dsd-enable" type="string">Disabled</PROPERTY>
<PROPERTY name="disk-dsd-enable-numeric" type="string">0</PROPERTY>
<PROPERTY name="disk-dsd-enable-pool" type="string">Disabled</PROPERTY>
<PROPERTY name="disk-dsd-enable-pool-numeric" type="string">0</PROPERTY>
<PROPERTY name="disk-dsd-delay" type="uint16">0</PROPERTY>
<PROPERTY name="disk-dsd-delay-pool" type="uint16">0</PROPERTY>
</OBJECT>
...
386 XML API basetype properties
Type
Description
Shows the period of inactivity in minutes after which available disks and global
uint16
spares will spin down, from 1–360 minutes. The default is 15 minutes. The value
0 means spin down is disabled.