HP P2000 G3 Cli Reference Manual page 373

Msa system
Hide thumbs Also See for P2000 G3:
Table of Contents

Advertisement

Table 20
controller-statistics properties (continued)
Name
Type
start-sample-
string
time-numeric
stop-sample-
string
time
stop-sample-
string
time-numeric
total-power-on-
string
hours
Example
# show controller-statistics
...
<OBJECT basetype="controller-statistics" name="controller-statistics" oid="1"
format="rows">
<PROPERTY name="durable-id" type="string">controller_A</PROPERTY>
<PROPERTY name="cpu-load" type="uint32">6</PROPERTY>
<PROPERTY name="power-on-time" type="uint32">171975</PROPERTY>
<PROPERTY name="write-cache-used" type="uint32">0</PROPERTY>
<PROPERTY name="bytes-per-second" units="KB" type="string">667.64KB</PROPERTY>
<PROPERTY name="bytes-per-second-numeric" type="string">667648</PROPERTY>
<PROPERTY name="iops" type="uint32">2</PROPERTY>
<PROPERTY name="number-of-reads" type="uint64">386768</PROPERTY>
<PROPERTY name="read-cache-hits" type="uint64">10192</PROPERTY>
<PROPERTY name="read-cache-misses" type="uint64">6097968</PROPERTY>
<PROPERTY name="number-of-writes" type="uint64">98020</PROPERTY>
<PROPERTY name="write-cache-hits" type="uint64">83360</PROPERTY>
<PROPERTY name="write-cache-misses" type="uint64">728185</PROPERTY>
<PROPERTY name="data-read" units="GB" type="string">100.01GB</PROPERTY>
<PROPERTY name="data-read-numeric" type="string">100017762304</PROPERTY>
<PROPERTY name="data-written" units="GB" type="string">11.80GB</PROPERTY>
<PROPERTY name="data-written-numeric" type="string">11807576064</PROPERTY>
<PROPERTY name="reset-time" type="string">2012-02-13 12:45:35</PROPERTY>
<PROPERTY name="reset-time-numeric" type="string">1329137135</PROPERTY>
<PROPERTY name="start-sample-time" type="string">2012-02-24 12:47:34</PROPERTY>
<PROPERTY name="start-sample-time-numeric" type="string">1330087654</PROPERTY>
<PROPERTY name="stop-sample-time" type="string">2012-02-29 10:19:57</PROPERTY>
<PROPERTY name="stop-sample-time-numeric" type="string">1330510797</PROPERTY>
<PROPERTY name="total-power-on-hours" type="string">911.48</PROPERTY>
</OBJECT>
...
Description
Unformatted start-sample-time value.
Date and time, in the format year-month-day hour:minutes:seconds,
when sampling stopped for the iops and bytes-per-second values.
Unformatted stop-sample-time value.
The total amount of hours the controller has been powered on in its life time.
HP P2000 G3 MSA System CLI Reference Guide 373

Hide quick links:

Advertisement

Table of Contents
loading