Table 10. I/O module port mapping in a six-bay chassis
Compute
IO Module A1 (Top)
sled
1a
1
1b
2
1c
3
1d
4
3
5, 6 (for half-width compute sled with quad-
port NDC)
5 (for half-width compute sled with dual-
port NDC)
4
7, 8 (for half-width compute sled with quad-
port NDC)
7 (for half-width compute sled with dual-
port NDC)
I/O module port mapping—two-bay chassis
In the two-bay chassis configuration that supports up to two full-width compute sleds, a compute sled is
mapped to four ports on each I/O module.
Figure 20. I/O module port mapping—full-width compute sleds
The following table lists the compute sleds and the ports to which they are mapped.
Table 11. I/O module port mapping—full-width compute sleds
Compute sled
1
3
I/O module port mapping—three-bay chassis
The three-bay chassis supports a combination of one full-width compute sled and up to two half-width
compute sleds.
I/O Module A1 (Top)
1, 2, 3, 4
5, 6, 7, 8
IO Module A2 (Bottom)
1
2
3
4
5, 6 (for half-width compute sled with quad-
port NDC)
5 (for half-width compute sled with dual-
port NDC)
7, 8 (for half-width compute sled with quad-
port NDC)
7 (for half-width compute sled with dual-
port NDC)
I/O Module A2 (Bottom)
1, 2, 3, 4
5, 6, 7, 8
29