Chassis Management Controller (Cmc) Specifications; Enclosure Control Panel Specifications; I/O Module Specifications; Environmental Specifications - Dell PowerEdge FX2 Owner's Manual

Hide thumbs Also See for PowerEdge FX2:
Table of Contents

Advertisement

Chassis Management Controller (CMC) specifications

Externally
Specifications
accessible
connectors
Remote
Two dedicated 10/100/1000 Mb RJ-45 (for integrated Ethernet remote access
management
controller). Gb port connects to the CMC module's external management network.
STK port allows CMCs in adjacent enclosures to be daisy chained. The STK port can
also be used for CMC NIC failover.
Serial
9-pin, DTE, 16550-compatible

Enclosure control panel specifications

Externally
Specifications
accessible
connectors
USB
One 4-pin, USB 1.1-compliant connector for keyboard and mouse support.
Video
15-pin VGA

I/O module specifications

NOTE: For information on the technical specifications for the I/O modules, see the I/O module
documentation at Dell.com/poweredgemanuals.

Environmental specifications

NOTE: For additional information about environmental measurements for specific system
configurations, see Dell.com/environmental_datasheets.
Temperature
Specifications
Maximum
20 °C/h (36 °F/h)
Temperature
Gradient
(Operating and
Storage)
Storage
–40 °C to 65 °C (–40 °F to 149 °F)
Temperature
Limits
Relative
Specifications
humidity
Storage
5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere must be non-
condensing at all times.
93

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge fx2sE24s