Note
If this setting is changed, the V-IPGW cards and/or V-SIPGW cards installed at the site will be deleted.
Default
Disable
Value Range
Disable, Enable
Maintenance Console Location
9.5 PBX Configuration—[1-1] Configuration—Slot—Site Property
VoIP-DSP Options
The settings in this tab relate to IP extensions and IP CO lines.
IP Extension Count of BGM
Specifies how many IP-PTs connected to the mother board can send out BGM.
Default
4
Value Range
0–117
Maintenance Console Location
9.5 PBX Configuration—[1-1] Configuration—Slot—Site Property
Feature Manual References
3.1.2 BGM (Background Music)
Echo Cancellation Ports
Specifies the number of ports to be used for echo cancellation.
Default
32
Value Range
0–64
Maintenance Console Location
9.5 PBX Configuration—[1-1] Configuration—Slot—Site Property