Panasonic KX-NS1000 Pc Programming Manual page 244

Pure ip-pbx
Hide thumbs Also See for KX-NS1000:
Table of Contents

Advertisement

9.5.1 PBX Configuration—[1-1] Configuration—Slot—Site Property—Main
Maintenance Console Location
9.5 PBX Configuration—[1-1] Configuration—Slot—Site Property
CNG Signal Effective Detection Width 2 (OFF)
Specifies the length of time that the PBX waits until another CNG signal is detected.
Default
3000 ms
Value Range
20–5000 ms
Maintenance Console Location
9.5 PBX Configuration—[1-1] Configuration—Slot—Site Property
CNG Signal Fixation Detection Counter
Specifies the number of times the CNG signal must be detected before the PBX proceeds the fax operation.
Default
1
Value Range
1–3
Maintenance Console Location
9.5 PBX Configuration—[1-1] Configuration—Slot—Site Property
CNG Signal Fixation Detection Pattern
Specifies the CNG signal pattern to be detected before the PBX proceeds the fax operation.
Default
OFF
Value Range
OFF, ON
Maintenance Console Location
9.5 PBX Configuration—[1-1] Configuration—Slot—Site Property
CED Signal Fixation Detection Time
Specifies the minimum length of time required for the CED (called station identification) signal to be detected
by the PBX.
Default
100 ms
244
PC Programming Manual
Document Version 2016-03

Advertisement

Table of Contents
loading

Table of Contents