9.22 PBX Configuration—[1-1]
Configuration—Slot— SLC2 - Card Property
The property for the extension cards can be specified.
SLT Pulse Dial Mode
Selects the type of pulse dial transmission appropriate to your area.
Default
Normal
Value Range
Normal, Sweden, New Zealand
Maintenance Console Location
9.22 PBX Configuration—[1-1] Configuration—Slot— SLC2 - Card Property
SLT Off Hook Time
Specifies the minimum length that a pulse dial sent from an SLT must be for the PBX to recognize it as an
off-hook signal.
Default
160 ms
Value Range
8 ´ n (n=3–255) ms
Maintenance Console Location
9.22 PBX Configuration—[1-1] Configuration—Slot— SLC2 - Card Property
SLT Off Hook Guard Time
Specifies the length of guard time used for off-hook signals from SLTs, to prevent the PBX mistaking them for
pulse dials.
Default
504 ms
Value Range
8 ´ n (n=12–63) ms
Maintenance Console Location
9.22 PBX Configuration—[1-1] Configuration—Slot— SLC2 - Card Property
Document Version 2016-03
9.22 PBX Configuration—[1-1] Configuration—Slot— SLC2 - Card Property
PC Programming Manual