Chapter 3
Device Management
1.
Load the new software image to the secondary memory bank:
2.
Configure the FTP server from which the new software files will be downloaded (see
"Downloading Software from an FTP Server"
3.
Download the software update files to the secondary memory bank (see
Software from an FTP Server"
4.
Verify the downloaded software files have been correctly saved to the secondary memory bank (see
Section 3.4.7, "Managing Memory Banks"
5.
Perform a trial run of the new software image:
On the SW Properties screen, click Run Secondary.
The device will reset and load the software image in the secondary memory bank. This process will take
approximately two minutes.
6.
Commit the new software image as the new default software:
Again on the SW Properties screen, click Set As Primary in order to set the current memory bank (currently
denoted Secondary) as Primary. Doing so will cause the software in the memory bank newly designated
Primary to be run by default on bootup.
Section 3.4.2

Viewing Software Properties

To view software properties, navigate to Management » SW Upgrade. The SW Properties screen appears.
Figure 16: SW Properties Screen
The table provides the following information:
Parameter
Current Active Bank
24
):
).
).
Section 3.4.6, "Downloading
Description
Synopsis:   { Primary, Secondary }
Displays the name of the memory bank from which the device
software is running.
RUGGEDCOM WIN
User Guide
Section 3.4.6,
Viewing Software Properties