RUGGEDCOM WIN
User Guide
2
6
7
8
Figure 55: Allowed BS Screen
1. Connect only to allowed BS List    2. Allowed BS List Table    3. Add Button    4. Delete Button    5. Connect only to allowed
Operator ID Box    6. Apply Button    7. Connect Button    8. Disconnect Button
2.
Click Disconnect.
Section 5.3.6

Connecting to Allowed Operator ID

Subscriber stations can be configured to only connect to a specific Operator ID. Once configured, the SS will only
connect to its own home Network Operator ID.
NOTE
Base station identifiers cannot be enabled or disabled if the RUGGEDCOM WIN is in scanning mode.
Click Disconnect before connecting to the base stations. Do not click Disconnect if using the RF
Interface. This will stop the RUGGEDCOM WIN from transmitting and it will lose its connection to the
base station(s). A hard reset (shutting down and then powering up) or a site visit will be required to
reboot the RUGGEDCOM WIN using the GUI.
For more information, refer to
1.
If this is the first time connecting to a base station, you must configure the scanner first. For more
information, refer to
Navigate to WiMAX » Allowed BS. The Allowed BS screen appears.
2.
Connecting to Allowed Operator ID
3
4
Section 5.3.5, "Disconnecting from Specific Base Stations"
Section 5.2.1, "Configuring the Scanner"