User configurations or operations are not required in this scenario. The SmartLogger can
automatically switch to an appropriate scheduling mode and deliver the scheduling command.
Figure 8-16 Communication scheduling
Active Power Control
Because of permission restriction, log in as Special User. Choose Settings > Active Power
Control to access the target page.
When Active Power Control Mode is set to Remote scheduling, the SmartLogger receives
the scheduling commands from the upstream NMS, converts them into valid command data
identifiable to the SUN2000s, and then sends the data to all the connected SUN2000s. Based
on the principle of preference of remote scheduling, the SmartLogger automatically sets
Active Power Control Mode to Remote scheduling after receiving a scheduling command
from the upstream NMS.