Step
3.
Configure the up/down
threshold.
4.
Return to system view.
5.
Enter MPLS TE view.
6.
Configure the flooding interval.

Controlling MPLS TE tunnel setup

Before performing the configuration tasks in this section, be aware of each configuration objective and
its impact on your device.
Perform the tasks in this section on the ingress node of the MPLS TE tunnel.
Enabling route and label recording
Perform this task to record the nodes that an MPLS TE tunnel traverses and the label assigned by each
node. The recorded information helps you know about the path used by the MPLS TE tunnel and the label
distribution information, and when the tunnel fails, it helps you locate the fault.
To enable route and label recording:
Step
1.
Enter system view.
2.
Enter MPLS TE tunnel interface
view.
3.
Record routes or record both
routes and labels.
Enabling loop detection
Enabling loop detection also enables the route recording function, regardless of whether you have
configured the mpls te record-route command. Loop detection enables each node of the tunnel to detect
whether a loop has occurred according to the recorded route information.
To enable loop detection:
Step
1.
Enter system view.
2.
Enter MPLS TE tunnel interface
view.
3.
Enable loop detection.
Command
mpls te bandwidth change
thresholds { down | up } percent
quit
mpls te
link-management
periodic-flooding timer interval
Command
system-view
interface tunnel tunnel-number [ mode
mpls-te ]
To record routes:
mpls te record-route
To record both routes and labels:
mpls te record-route label
Command
system-view
interface tunnel tunnel-number
[ mode mpls-te ]
mpls te loop-detection
74
Remarks
By default, the up/down threshold
is 10% of the link reservable
bandwidth.
N/A
N/A
By default, the flooding interval is
180 seconds.
Remarks
N/A
N/A
By default, both route
recording and label
recording are disabled.
Remarks
N/A
N/A
By default, loop detection is
disabled.