NEC Express5800 series User Manual page 149

Hide thumbs Also See for Express5800 series:
Table of Contents

Advertisement

Table 5-1. POST Error Codes and Messages (continued)
Error Code and Message
0B7C
An error occurred
during the redundant
power module
confirmation
0B7D
Normal operation
can not be
guaranteed with use
of only one PSU
0B80
BMC Memory Test
failed
0B81
BMC Firmware Code
Area CRC check
failed
0B82
BMC core hardware
failure
0B83
BMC check failure
0B8A
BMC SEL area full
0B8B
BMC progress check
timeout
0B8C
BMC command
access failed
0B8D
Could not redirect
the console – BMC-
busy
0B8E
Could not redirect
the console BMC
error
OB8F
Could not redirect
the console BMC
parameter error
0B90
BMC Platform
Information Area
corrupted
0B91
BMC update
firmware corrupted
0B92
Internal Use Area
Error
0B93
BMC SDR
Repository empty
Description
An error occurred while redundant
power supply was configured.
System is running on only one
power supply
BMC SRAM test error
CRC error occurred in BMC code
area
A firmware task cannot be
completed due to BMC hardware
error.
BMC 1BF or OBF check failed
BMC SEL area full
BMC progress check timeout
BMC command access failed
Could not redirect the console –
BMC- busy
Could not redirect the console
BMC error
Could not redirect the console
BMC Parameter error
The platform information area of
BMC is damaged
BMC update firmware corrupted
Internal Use Area of BMC FRU
corrupted
No BMC SDR data exists
Action
Contact your service representative to
replace the power unit.
Contact your service representative to
replace the power unit.
Turn OFF server power source once
and then on again to start the server. If
the error cannot be corrected, contact
your service representative.
All the commands and functions other
than the FRU command and the EMP
function can be used. This is not a fatal
error. Turn off the power once and then
on again to restart the server. If the
error cannot be corrected, contact your
service representative.
Turn OFF server power source once
and then on again to start the server. If
the error cannot be corrected, contact
your service representative.
Problem Solving 5-17

Advertisement

Table of Contents
loading

This manual is also suitable for: