Detailed description

2.13 Control behavior in specific operating states

2.13
Control behavior in specific operating states
2.13.1

Power On

No synchronized actions are active during ramp-up of the NC (Power On).
Synchronized actions that are to be active immediately after the ramp-up of the NC (Power
On), must be event-driven as static synchronized actions within an ASUB or activated via the
PLC user program.
References
Detailed information on the activation of synchronized actions after ramp-up of the NC
(Power On) can be found in:
PLC user program
Function Manual, Basic Functions; PLC Basic Program for SINUMERIK 840D sl
Section "Structure and functions of the basic program" > "Functions of the basic program
with call from the user program"
Event-driven
Function Manual, Basic Functions; Mode Group, Channel, Program Operation (K1)
Section "Program operation" > "Event-controlled program calls"
2.13.2

NC reset

State after NC reset:
From:
Synchronized action
Traversing motion
Speed-controlled
spindle
Master value
coupling
Measuring
130
Modal and non-modal synchronized action (ID)
Aborted or inactive
MD35040 $MA_SPIND_ACTIVE_AFTER_RESET = <value>
MD20110 $MC_RESET_MODE_MASK, bit 13 = <value>
The traversing motions are aborted
TRUE ⇒ The spindle remains active
FALSE ⇒ The spindle is stopped
1 ⇒ The coupling remains active
0 ⇒ The coupling is released
Aborted
Function Manual, 07/2012, 6FC5397-5BP40-3BA0
Static synchronized action (IDS)
Active
Synchronized actions