Siemens SINUMERIK 828D Function Manual page 60

Synchronized actions
Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

Detailed description
2.5 Language elements for synchronized actions and technology cycles
Table 2- 3
Settable addresses: Travel to fixed stop
FXS
FXST
FXSW
FOCON
FOCOF
1) Section: "Travel to fixed stop (FXS, FXST, FXSW, FOCON, FOCOF, FOC) (Page 114)"
Table 2- 4
Settable addresses: Couplings > Generic coupling
CPBC
CPDEF
CPDEL
CPFMOF
CPFMON
CPFMSON
CPFPOS
CPFRS
CPLCTID
CPLDEF
CPLDEL
CPLDEN
CPLNUM
CPLDYPRIO
CPLDYVLL
CPLDYVLU
CPLINSC
CPLINTR
CPLOF
CPLON
CPLOUTSC
CPLOUTTR
CPLPOS
CPLSETVAL
CPMALARM
CPMPRT
CPMRESET
CPMSTART
CPMPVDI
CPOF
60
1)
Activate travel to fixed stop
Torque limit for travel to fixed stop
Monitoring window for travel to fixed stop
Activate travel with limited torque/force
Deactivate travel with limited torque/force
1)
Block change criterion with active coupling
Create coupling module
Delete coupling module
Behavior of the following axis when switching off the coupling
Behavior of the following axis when switching on the coupling
Synchronization mode during coupling
Synchronized position of the following axis when switching on
Reference system for the coupling module of the following axis
Number of the curve table for the coupling of the following axis
Definition of the reference: Leading axis to following axis
Cancellation of the reference: Leading axis to following axis
Coupling factor: Numerator
Coupling factor: Denominator
Priority of the leading axis for the dynamic limitation
Limitation of the overlaid motion of the leading axis: Lower limit
Limitation of the overlaid motion of the leading axis: Upper limit
Scaling factor for the input value of the leading axis
Offset value for the input value of the leading axis
Coupling of leading axis to following axis: Switch off
Coupling of leading axis to following axis: Switch on
Scaling of the output value
Offset of the output value
Synchronized position of the leading axis when switching on
Coupling type of the following axis to the leading axis
Define alarm behavior
Define start behavior for program test
Define reset behavior
Define start behavior
Define behavior regarding NC/PLC interface signals
Deactivation of the coupling to all defined leading axes
Function Manual, 07/2012, 6FC5397-5BP40-3BA0
Synchronized actions

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840d slSinumerik 840de sl

Table of Contents