Mitsubishi Electric Q172CPU Programming Manual page 49

Motion controller, virtual mode
Hide thumbs Also See for Q172CPU:
Table of Contents

Advertisement

4 POSITIONING DEDICATED SIGNALS
(3) Error detection signal (M2407+20n) .......................... Status signal
(a) This signal turns on with detection of a minor error or major error, and it is
used as judgement of the error available/not available.
The applicable error code
register with detection of a minor error. (Refer to Section 4.2.1 (4))
The applicable error code
register with detection of a major error. (Refer to Section 4.2.1 (5))
(b) This signal turns off when the error reset command (M3207+20n) turns on.
Error detection
Error detection signal
OFF
(M2407+20n)
Error reset command
OFF
(M3207+20n)
REMARK
(Note-1) : Refer to APPENDIX 2 for the error codes with detection of major/minor
errors.
(4) Servo error detection signal (M2408+20n) ................. Status signal
(a) This signal turns on when an error occurs at the servo amplifier side (except
for errors cause of alarms and emergency stops)
judgement of the servo error available/not available.
When an error is detected at the servo amplifier side, the applicable error
(Note-1)
code
Section 4.2.1).
(b) This signal turns off when the servo error reset command (M3208+20n)
turns on or the servo power supply turns on again.
Servo error detection
Servo error detection signal
(M2408+20n)
Servo error reset command
(M3208+20n)
REMARK
(Note-1) : Refer to APPENDIX 2.5 for the error codes on errors detected at the
servo amplifier side.
(Note-1)
is stored in the minor error code storage
(Note-1)
is stored in the major error code storage
ON
is stored in the servo error code storage register (Refer to
ON
OFF
OFF
4 - 18
ON
(Note-1) ,
and it is used as
ON