Mitsubishi Electric MELSEC Q Series User Manual page 180

Ethernet/ip network interface module for programmable controller
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

7
UTILITY PACKAGE (SW1DNC-EIPUTL-E)
(4) Refreshing send/receive data of Tag communication
Setting the refresh target
device
Set for each tag
Set for each input and output
area
(5) Precautions
7
- 53
7.9 "Setting" Tab (Parameter Settings)
7.9.7 "Refresh Parameter" window
Setting is available in either way of the following.
Table 7.25 Send/receive data of Tag communication refreshing
Refresh target device can be set for each tag.
The refresh target devices can be kept unchanged even when Tag
Parameter is added or deleted. (
and data sizes)
However, the number of settings needs to be checked.
(
Section 7.1 (1) The number of auto refresh parameter
settings)
Set the refresh target device for each input and output area.
Setting can be completed on one window.
However, the refresh target devices may change when Tag
Parameter is added or deleted. (
and data sizes)
The followings are the precautions for setting the refresh target device.
• When setting the size in "Data Area" and "Extension Data Area" of the "Refresh
Parameter" window, ensure that it is equal to or smaller than the size set in the
"Add Own Nic" window.
• The number of auto refresh parameter settings that can be made is limited.
(
Section 7.1 (1) The number of auto refresh parameter settings)
Description
Section 5.2.1 (2) Tag types
Section 5.2.1 (2) Tag types
Setting window
•"Producer Tag" window
•"Consumer Tag" window
•"Message Tag" window
"Refresh Parameter" window