9.12 Upper base ASSY

(1) Release the LCD PCB flat cable, the sensor PCB flat cable, the second side CCD flat
cable and the sensor PCB FG harness from the securing fixtures. Turn over the
machine, and pull the cover release lever to open the upper base ASSY.
(2) Pull the left side of upper base ASSY to remove the boss, and remove it.
Cover release lever
Assembling Note:
• When attaching the upper base ASSY to the lower base, the rib of upper base ASSY
has to be inner than the rib of lower base.
Fig. 3-28
Rib of lower base
Fig. 3-29
3-26
Upper base ASSY
Rib of Upper base ASSY
Confidential