Handling The Log Cycles; General Information; Cycle100 Logging On; Cycle101 Logging Off - Siemens SINUMERIK 840D sl Programming Manual

Measuring cycles
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Miscellaneous functions
7.1 Log measurement results
7.1.3

Handling the log cycles

7.1.3.1

General information

Function
• The log is enabled and disabled via the program (CYCLE100/CYCLE101). This requires
• After disabling the log function, the log files can be exported from the part program
Operational sequence
When used with the measuring cycles, it is sufficient to activate and deactivate the logging
with CYCLE100 and CYCLE101 respectively. Logging is undertaken under the parameters
described in Sections "Selection of log content", "Log format" and "Log header".
Logging is executed by CYCLE105, CYCLE106, CYCLE113, and CYCLE118. These cycles
are called up in conjunction with measuring cycles.
The log cycles may be used independently of the measuring cycles. CYCLE100 and
CYCLE101, and CYCLE105 and CYCLE106 are called explicitly in this context. CYCLE113
and CYCLE118 are called internally. You can also be called separately, if necessary.
See also
Selection of the log content (Page 7-6)
Log format (Page 7-7)
Log header (Page 7-8)
7.1.3.2

CYCLE100 Logging ON

After the log is enabled, an existing file with the specified name is automatically deleted in
the control. All follow-up logs with _PROTNAME[1]_digit are only deleted when the preceding
logs overflow. The log is reopened and the header is entered. The internal status variables
are set.
7.1.3.3

CYCLE101 Logging OFF

Disables the logging function and resets the internal flag.
7-2
a cycle call without setting any parameters.
memory to diskette (HMI Advanced only) or via V.24.
Programming Manual, Release 04/2006, 6FC5398-4BP10-0BA0