7.2.4.3

Calibrate tool probe - CYCLE_CAL_TOOLSETTER

With CYCLE_CAL_TOOLSETTER
Softkeys
or
Softkeys
measuring cycles CYCLE971 and CYCLE972 can be parameterized to calibrate a tool
measuring probe.
Parameter
Parameter
_MA
_PRNUM
_FA
7.2.4.4

Calibration on surface - CYCLE_CAL_PROBE

With CYCLE_CAL_PROBE
Softkeys
or
softkeys
measuring cycles CYCLE973 and CYCLE976 can be parameterized to calibrate a surface.
Parameter
Parameter
_SETVAL
_MA
_MD
_PRNUM
_MVAR
Measuring cycles
Programming Manual, Release 04/2006, 6FC5398-4BP10-0BA0
7.2 Measuring cycle support in the program editor (up to measuring cycles SW 5.4)
Type
Value
INTEGER
INTEGER
>0
INTEGER
>0
INTEGER
REAL
>0
Type
Value
INTEGER
REAL
INTEGER
1...3
INTEGER
0, 1
INTEGER
>0
INTEGER
≥0
(CYCLE971)
(CYCLE972)
Meaning
Selection: Cycle number
971...for CYCLE971 (milling machine),
972...for CYCLE972 (turning machine)
Number of measuring axis and for CYCLE972 also the offset
axis
Probe number
For CYCLE971 only
Selection: Measuring variant
0...absolute calibration/1...incremental calibration
Measurement path
Meaning
Selection: Cycle number
976...for CYCLE976 (milling machine),
973...for CYCLE973 (turning machine)
Calibration setpoint with respect to workpiece zero
Number of the measuring axis
Measuring direction
Probe number
Selection: Measuring variant (for CYCLE976 only)
0: Calibration on any surface
Miscellaneous functions