Gasfiring - Siemens LMV5 Series Technical Instructions

Linkageless burner management system
Hide thumbs Also See for LMV5 Series:
Table of Contents

Advertisement

LMV Series
LEGEND - Password Access: (U)=User, (S)=Service, (O)=OEM, Shaded = Commonly Used, ** = Must Set, X = Has Function, / = Partial Function
Menu Path
Parameter
O2Ctrl/LimitrGas (S)
O2Ctrl/LimitrOil (S)
LC Analog Output (S)
allowed Pot.diff (S)
Params & Display>
SystemConfig
OptgMode COx Gas (S)
OptgMode COx Oil (S)
AirTempX60PT1000 (O)
GasFiring (U)
OilStage1/Mod (U)
OilStage2 (U)
Params & Display>
OilStage3 (U)
HoursRun>
TotalHoursReset (U)
TotalHours (U)
SystemOnPower (U)
GasFiring (U)
OilStage1/Mod (U)
Params & Display>
HoursRun>
OilStage2 (U)
Reset
OilStage3 (U)
TotalHoursReset (U)
GasStartCount (U)
OilStartCount (U)
Params & Display>
StartCounter
TotalStartCountR (U)
TotalStartCount (U)
GasStartCount (U)
Params & Display>
StartCounter>
OilStartCount (U)
Reset
TotalStartCountR (U)
SCC Inc.
Default
Range
See
man deact
See: Params & Display > O2Contr/Alarm > GasSettings > OptgMode
Description
See
Load
See: Params & Display > LoadController > Configuration > Analog Output > OutValuSelection
Description
Sets the allowable difference between channels A and B of the actuator's potentiometer.
15
10-15
Units are tenths of a degree, so 10 = 1.0 degrees.
deactivated
deact
COx Control
Future functionality. Does nothing at this time.
deact
COx Limiter
activated
deact
See: Params & Display > O2 Module> Configuration > AirTempX60PT1000
deactivated
Hours run firing gas. Can be adjusted here. See: Operation > HoursRun
Hours run on modulating or stage 1 oil. Can be adjusted here. See: Operation > HoursRun
0
0-999999 hr
Hours run on stage 2 oil. Can be adjusted here. See: Operation > HoursRun
Hours run on stage 3 oil. Can be adjusted here. See: Operation > HoursRun
Hours run on all fuels. Can be adjusted here. See: Operation > HoursRun
Read Only
These values CANNOT be adjusted or reset. See: Operation > HoursRun
Read Only
Hours run firing gas. Can be reset here. See: Operation > HoursRun
Hours run on modulating or stage 1 oil. Can be reset here. See: Operation > HoursRun
Reset Only
Hours run on stage 2 oil. Can be reset here. See: Operation > HoursRun
Hours run on stage 3 oil. Can be reset here. See: Operation > HoursRun
Hours run on all fuels. Can be reset here. See: Operation > HoursRun
Number of starts for gas. Can be adjusted here. See: Operation > StartCounter
0
0-999999 hr
Number of starts for oil. Can be adjusted here. See: Operation > StartCounter
Total number of starts. Can be adjusted here. See: Operation > StartCounter
Read Only
Total number of starts. Cannot be reset.
Number of starts for gas. Can be reset here. See: Operation > StartCounter
Reset Only
Number of starts for oil. Can be reset here. See: Operation > StartCounter
Total number of starts. Can be reset here. See: Operation > StartCounter
Page 44
HOME
Description
P - LIST
Technical Instructions
LV5-1000
LMV
x x
x x x
x x x
x
x
x x
x x x
x x x
x x x
x x x
x x x
x x x
x x x
x x x
x x x
x x x
x x x
x x x
x x x
x x x
x x x
x x x
x x x
x x x
x x x