Rexroth IndraDrive Integrated Safety Technology "Safe Torque Off" (as of MPx-16)
Safety zone node
12.4

Technical data of inputs and outputs

12.4.1

Digital inputs (safety technology L options)

LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Passive safety unit with internal dynamization pulses in conjunction with
external safety technology contacts and an external 24V power supply
unit
Active safety unit via a safety PLC
Passive safety unit
ext.
External safety unit for a safety zone
X
Connection point of the safety zone beginner
Tab. 12-21:
Signal input
When a KSM/KMS with optional safety technology is to be a safety zone
node within a safety zone, X141 must be equipped with the connector
RBS0023.
KSM/KMS without optional safety technology do not require the connector,
because for these devices the signals are directly transmitted to the next
safety zone node via X103.1 and X103.2. KSM/KMS without optional safety
technology are not safety zone nodes and do not react to safety technology
signals.
The digital inputs correspond to IEC 61131, type 2.
Fig. 12-12:
Symbol
Bosch Rexroth AG
Project planning
Active safety unit
int. Dyn: Dynamization pulses are
internally generated