Technical Data

10.1
General Technical Data
Input
Power supply voltage
Power supply frequency
Output
Rated output voltage
Rated power
Output frequency
Switching frequency
Frequency converter efficien‐
cy
Overload capability
Main functions
Control mode
V/F curve
Speed regulation range
Start-up torque
Frequency resolution
Frequency control accuracy
Multiple speed control
Acceleration/deceleration
curve mode
DC brake
1 AC 200 ~ 240 V (-10 % / +10 %)
3 AC 380 ~ 480 V (-15 % / +10 %)
50 ~ 60 Hz (±5 %)
Corresponding to input voltage
0.4 ~ 2.2 kW (1P AC 200 ~ 240 V)
0.4 ~ 4.0 kW (3P AC 380 ~ 480 V)
0 ~ 400 Hz
1 ~ 15 kHz
>95%
150 % of rated current for 60s, and then 100 % of rat‐
ed current for 540s
200 % of rated current for 1s, and then 100% of rated
current for 19s
V/F control
Linear mode, square curve mode, user-defined multi-
point curve mode
1:50
150 % * rated torque at 3 Hz
100 % * rated torque at 1.5 kHz
Analog setting: 1/1000 of max. frequency
Digital setting: 0.01 Hz
Analog setting: ±0.1 % of max. frequency (25 ± 10 ℃)
Digital setting: ±0.01 % of max. frequency (-10 ~ 50 ℃)
Via simple PLC or control terminals
Linear, S-curve
DC brake activation frequency: 0 ~ 50 Hz
DC brake time: 0 ~ 20s