Starting configuration
Function
Name
code
b1.30
Starting mode
Starting
b1.31
frequency
Starting
b1.32
frequency
holding time
Starting DC
b1.33
braking time
Starting DC
b1.34
braking current
b1.35
~
Reserved
b1.39
Stopping configuration
Function
Name
code
b1.40
Stopping mode
Stopping DC
b1.41
braking initial
frequency
Stopping DC
b1.42
braking time
202/235
Setting range
0: Start directly
1: Braking before start
2: Start with speed capture
0.00 ~ 50.00 Hz
0.0 ~ 20.0s
0.0 ~ 20.0s (0.0 represents
no
action of starting DC braking)
0.0 % ~ 150.0 %
(Rated frequency converter
current)
Setting range
0: Deceleration to stop
1: Freewheeling to stop
2: Freewheeling under
STOP-command, decelerat‐
ing under direction change
0.00 ~ 50.00 Hz
0.0 ~ 20.0s
(0.0 represents no action of
stopping DC braking)
DOK-RCON03-EFC-3600***-IT01-EN-P
Rexroth Frequency Converter EFC 3600
Min.
unit
1
0.01 Hz 0.05 Hz
0.1s
0.1s
0.1 %
Factory
Min. unit
default
1
0.01 Hz 0.00 Hz
0.1s
Factory
Attribute
default
0
STOP
STOP
0.1s
STOP
0.0s
STOP
0.0 %
STOP
Attribute
0
STOP
STOP
0.0s
STOP