Bosch Rexroth EFC 3600 Operating Instructions Manual page 198

Frequency converter
Hide thumbs Also See for Rexroth EFC 3600:
Table of Contents

Advertisement

Bosch Rexroth AG
Appendix
Function
Name
code
Access authority
b0.02
setting
b0.03
Reserved
b0.04
Reserved
System configuration
Function
Name
code
Parameter
b0.05
initialization
Parameter
b0.06
replication
b0.07
~
Reserved
b0.19
Frequency Converter configuration
Function
Name
code
Frequency converter
b0.20
rated voltage setting
b0.21
Carrier frequency
196/235
Setting range
0: Basic parameters
1: Standard parameters
2: Extended parameters
3: Advanced parameters
4: Start-up mode
Setting range
0: No action
1: Restore factory default
2: Remove error record
Note: The value is automatically
set to be 0 after the operation.
0: No action
1: Read parameter
2: Write parameter
Note: The value is automatically
set to be 0 after the operation.
Setting range
200 V: 200 ~ 240 V
400 V: 380 ~ 480 V
1 ~ 15 kHz
DOK-RCON03-EFC-3600***-IT01-EN-P
Rexroth Frequency Converter EFC 3600
Min.
unit
1
Min.
unit
1
1
Min.
Factory
unit
default
220 V
1 V
380 V
1 kHz
4 kHz
Factory
Attribute
default
RUN/
0
STOP
Factory
Attribute
default
0
STOP
0
STOP
Attribute
STOP
RUN/STOP