17.2.10
Group E3: PID Function
PID basic configuration
Function
Name
code
PID reference
E3.00
channel
PID feedback
E3.01
channel
E3.02
Reserved
Analog
E3.03
digital setting
Rotation speed
E3.04
digital setting
E3.05
~
Reserved
E3.09
PID control
Function
Name
code
P: Proportional
E3.10
gain
E3.11
Ti: Integral time
Setting range
0: No PID control
1: Panel potentiometer
2: Panel digital setting
3: Analog input AIV
4: Analog input AIC
5: Analog digital
setting [E3.03]
6: Rotation speed
digital setting [E3.04]
7: Communication
0: AIC
1: AIV
0.00 ~ 10.00 V
0 ~ 30000 rpm
Setting range
0.0 ~ 10.000
0.00 ~ 100.00s
(0.00 represents no integral)
Bosch Rexroth AG
Appendix
Min.
Factory
Attribute
unit
default
1
0
1
0
0.01
0.00
1 rpm
0 rpm
Min.
Factory
Attribute
unit
default
0.001
1.500
0.01s
0.00s
STOP
STOP
RUN/
STOP
RUN/
STOP
RUN/
STOP
RUN/
STOP
219/235