OceanStor N8500 Clustered NAS Storage System
Installation Guide (for T Series V100R005)
Figure 7-40 Indicators on the Fibre Channel switch
Table 7-6 Checklist of indicators on the Fibre Channel switch
NO.
1
2
3
Issue 02 (2015-09-22)
Indicator Name
System Status
LED indicator
Fibre Channel
Port Status LED
indicator
Ethernet Speed
indicator
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
7 N8500 Installation (with S5600T, S5800T or S6800T
Storage System as the Storage Unit)
Description
l Green and on: System is on and functioning
properly.
l Amber and on (for more than five seconds): A
system fault has occurred.
l Amber or Green and blinking: Attention is
required. A number of variables can cause this
status including a single power supply failure, a
fan failure, or one or more environmental ranges
has exceeded.
l Off: System is off or there is no power.
l Green and slow blinking (2 seconds): Online but
segmented (loopback cable or incompatible
Fibre Channel switch).
l Green and fast blinking (0.5 second): Internal
loop-back (diagnostic).
l Green and Flickering: Online, frames flowing
through port.
l Green and on: Port is online (connected to
external device) but has no traffic.
l Amber and blinking (2 seconds): Port is disabled
(because of diagnostics or the portdisable
command).
l Amber and blinking (0.5 second): Port is faulty.
l Amber and on (for more than 5 seconds): Port
is receiving light or signal carrier at 4 Gbit/s; but
is not yet online.
l Off: No light or signal carrier on media
interface.
l Green and on: Port speed is 100 Mbit/s.
l Off: Port speed is 10 Mbit/s.