Solution - Siemens SINAMICS S120 Manual

Entering limit values for safely limited speed (sls) into a sinamics s120 via profisafe with profinet
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

2 Solution

Component
Terminals for the
load resistors
(R1...R8)
Load resistor R9
Terminals for load
resistor (R9)
The application example was tested with the hardware components listed here.
Note
Alternatively, other components with the same function may be used. In such a
case, a different parameter assignment and different wiring of the components
may be required.
The components marked in yellow are not relevant for this function example.
Standard software components
Table 2-3: Engineering software
Component
STEP 7
S7 Distributed Safety
Programming
S7 F configuration
pack
STARTER
Sample files and projects
The list below contains all the files and projects used in this example.
Table 2-4: Documents and files
MC_FE_I_019_V10.zip
81682475_MC_FE_I_019_V10_en.pdf
14
Type
ST 2.5-QUATTRO-TG
P-CO component
connector
SMA0207 1K2 1% TK
TERMINALS_ACCES
SORY_EMPTY_CON
NECTOR_TYPE1_G
RAY
TERMINAL_4-
WIRE_GRAY
Qty.
Order number
1
6ES7810-4CC10-0YA7
1
6ES7833-1FC02-0YA5
1
1
6SL3072-0AA00-0AG0
Component
MLFB/ ordering data
3038451
3036796
RES_MET_FLM_1K2
_+-
1%_600mW_+50ppm
_0207
280-801
280-686
Version
V5.5 SP2 HF1
V5.4 SP5
V5.5 SP10
V4.3.2.0
Note
This zipped file contains the
project.
This document
PROFIsafe SLS Override
Version 1.0, Entry ID: 81682475
Qty
Manufacturer
Phoenix
8
Contact
Phoenix
8
Contact
1
Beyschlag
1
WAGO
WAGO
1

Advertisement