4 Configuration and project engineering
No.
Action
Now make the
basic settings,
with which the safety mode of
the F-CPU
6.
being used is activated. To do
this, open the properties window
(by double-clicking on the F-
.
CPU)
Here, go to the "Protection" tab.
Activate the safety mode by
setting a checkmark for "CPU
contains safety program".
As protection level, select
level 1, and activate password-
7.
protected access.
Assign a password
for the safety program.
0 is used as password in this
particular example.
Click "OK" to confirm the data
that have been entered.
Now insert the
F-DI module of the safety
demonstration case
by dragging and dropping.
In this example
8.
an "FDI24xDC24V"
module is used.
Then open the properties of the
module by double-clicking on the
module.