Siemens SINAMICS S120 Manual page 49

Entering limit values for safely limited speed (sls) into a sinamics s120 via profisafe with profinet
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

No.
Action
FB1
4.
In this example, the actual
safety program is created in an
FB function block.
Please insert such a block into
the block folder. Then assign the
"FB1" name, and as
programming language select
"F-FDB" (=F-FUP).
Network 1:
The automatic acknowledgment
is activated in this network.
Network 2:
Safety function STO is
controlled using switch -S1.
Network 3:
In this network, all of the safety
functions on the drive that are
not required
are permanently deselected.
This applies to SS1, SS2,
SOS, SLP and SDI+/-.
Network 4:
Safety function SLS is controlled
using switch -S2 or -S3.
PROFIsafe SLS Override
Version 1.0, Entry ID: 81682475
4 Configuration and project engineering
Remark
49