Siemens SINAMICS S120 Manual page 8

Entering limit values for safely limited speed (sls) into a sinamics s120 via profisafe with profinet
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

1 Task
Overview of the automation task
The following diagram provides an overview of the automation task.
Figure 1-1: Concept of the safety functions
The following safety functions are used as basis for further consideration.
Table 1-3: Safety functions of the application example
Safety function
8
Actuating the Emergency
SF1
Stop button
When the protective door is
open, it is not permissible
that the drive exceeds the
SF2
velocity/speed configured by
the user.
(high limit value)
Description
STO:
Safe shutdown of the drive
torque.
SLS:
Monitoring of the drive
speed.
Version 1.0, Entry ID: 81682475
Response
PROFIsafe SLS Override

Advertisement

Table of Contents
loading

Table of Contents