Cooling Fan Circuit Pressure Test - Toro Reelmaster 7000-D Service Manual

Hide thumbs Also See for Reelmaster 7000-D:
Table of Contents

Advertisement

Cooling Fan Circuit − Pressure Test
#4
#1
1.6 CID
1.6 CID
1450 psi
1450 psi
FRONT
M1
M2
MV1
OR1
.040
SP1
G1
RV1
P1
MOW CONTROL
MANIFOLD
50 psi
High Pressure
Low Pressure
Return or Suction
Flow
Hydraulic System
REEL
MOTORS
#5
#2
1.6 CID
1.6 CID
1450 psi
1450 psi
M4
M3
MV2
CV1
CV2
OR2
.040
110 psi
110 psi
SP2
LC1
LC2
3000 psi
3000 psi
RV2
T1
T2
P2
OIL COOLER
RETURN FILTER
#3
1.6 CID
FAN
MOTOR
1450 psi
REAR
0.51 CID
M1
M2
S1
G1
CV
G2
PRV
P1
PRESSURE
G2
GAUGE
12.1 GPM
12.1 GPM
Page 5 − 76
STEERING
CYLINDER
EXTEND
STEERING
TO TURN RIGHT
UNIT
6.1
CIR
1050 psi
P
T
3.3 GPM
ST
50/50 SPLIT
L
FD
T
P2
FAN CONTROL
MANIFOLD
6.6 GPM
6.6 GPM
GEAR
PUMP
0.56
0.56
1.03
CID
CID
CID
P5
P4
P3
STRAINER
BREATHER
Reelmaster 7000−D
E
TO CHARGE
CIRCUIT
TO LIFT
MANIFOLD
1.03
CID
P2