Address
Purpose
Dec (Hex)
CH1
CH2
147
307
For designation
(93H)
(133H)
of transmission
control
148
308
(94H)
(134H)
149
309
(95H)
(135H)
150
310
For designation
(96H)
(136H)
of
communication
control
151
311
(97H)
(137H)
152
312
(98H)
(138H)
153
313
For designation
(99H)
(139H)
of half-duplex
communications
control (for RS-
232)
154
314
(9AH)
(13AH)
155
315
For designation
(9BH)
(13BH)
of
communication
control
156
316
For designation
(9CH)
(13CH)
of data
communication
time monitoring
157
317
(9DH)
(13DH)
158
318
(9EH)
(13EH)
159
319
Use prohibited
(9FH)
(13FH)
APPENDICES APPENDIX
500
Appendix 3 Buffer Memory
Name
DTR/DSR (ER/DR), DC control designation
• Transmission control (b0)
0: DTR/DSR control
1: DC code control
• DC1/DC3 control (b8)
0: Control disabled
1: Control enabled
• DC2/DC4 control (b9)
0: Control disabled
1: Control enabled
DC1/DC3 (Xon/Xoff) code designation
• DC1 code (b0 to b7)
00H to FFH: DC1 code
• DC3 code (b8 to b15)
00H to FFH: DC3 code
DC2/DC4 code designation
• DC2 code (b0 to b7)
00H to FFH: DC2 code
• DC4 code (b8 to b15)
00H to FFH: DC4 code
Word/byte units designation
0: Word units 1: Byte units
CD terminal check designation (for RS-232)
0: Check 1: Do not check
Communication method designation (for RS-
232)
0: Full duplex communication 1: Half-duplex
communication
Simultaneous transmission priority/non-priority
designation
0: Priority
1 to 255: Non-priority (transmission wait time,
unit: 100 ms)
Retransmission time transmission method
designation
0: Do not resend 1: Resend
Simultaneous transmission data valid/invalid
designation
• Receive data enable/disable (b0)
0: Enable 1: Disable
• Send data enable/disable (b8)
0: Enable 1: Disable
No-reception monitoring time (timer 0)
designation
0H: Unlimited wait
28H to FA0H: Monitoring time (unit: byte)
Response monitoring time (timer 1) designation
0H: Unlimited wait
1H to BB8H: Monitoring time (unit: 100ms)
Send monitoring time (timer 2) designation
0H: Unlimited wait
1H to BB8H: Monitoring time (unit: 100ms)
System area
Defaul
Protocol
t value
MC
Non Bi
0
RW
1311H
1412H
0
RW
1
RW
0
0
0
0
RW
0
RW
32H (5
RW
RW
second
s)
708H (3
RW
minutes
)
Reference
Pd
Page 236 DATA
COMMUNICATIONS
USING DC CODE
TRANSMISSION
CONTROL
Page 225
CHANGING DATA
LENGTH UNITS TO
BYTE UNITS
(WORD/BYTE
UNITS SETTING)
MELSEC iQ-R Serial
Communication
Module User's
Manual (Startup)
Page 243 DATA
COMMUNICATIONS
USING HALF-
DUPLEX
COMMUNICATIONS
Page 227
CHANGING DATA
COMMUNICATION
MONITORING TIME

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents