Mitsubishi Electric MELSEC iQ-R Series User Manual page 532

Serial communication module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

■Data example
• The following table shows data to be stored in the data storage area when the string of send data is 'ABCD'.
(Reference: A=41H, B=42H, C=43H, and D=44H in ASCII code)
Item
Fixed length/Variable length
Data length
Start address of data storage area
Unit of stored data
Byte swap
Data to be stored in data storage
area
• The following table shows data to be stored in the data storage area when the string of send data is 'EFG'.
(Reference: E=45H, F=46H, and G=47H in ASCII code)
Item
Fixed length/Variable length
Data length
Start address of data storage area
Unit of stored data
Byte swap
Data to be stored in data storage
area
APPENDICES APPENDIX
530
Appendix 5 Operation Image and Data Structure of Predefined Protocol
Description
Fixed length
4 bytes
D0
Lower byte + Upper byte
Disable
Enable
D0=4241H
D0=4142H
D1=4443H
D1=4344H
Description
Fixed length
3 bytes
D0
Lower byte + Upper byte
Disable
Enable
D0=4645H
D0=4546H
D1=0047H
D1=4700H
Lower bytes only
Disable
Enable
D0=0041H
D0=0042H
D1=0042H
D1=0041H
D2=0043H
D2=0044H
D3=0044H
D3=0043H
Lower bytes only
Disable
Enable
D0=0045H
D0=0046H
D1=0046H
D1=0045H
D2=0047H
D2=0047H
D3= (any data)
D3= (any data)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents