Mitsubishi Electric MELSEC iQ-R Series User Manual page 514

Serial communication module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Address
Purpose
Dec (Hex)
CH1
CH2
8277
8533
For designation
(2055H)
(2155H)
of
programmable
controller CPU
monitoring
function
8278
8534
(2056H)
(2156H)
8279
8535
(2057H)
(2157H)
8280
8536
(2058H)
(2158H)
8281 to
8537 to
8361
8617
(2059H to
(2159H to
20A9H)
21A9H)
8362 to
8618 to
Use prohibited
8421
8677
(20AAH
(21AAH
to
to
20E5H)
21E5H)
8422
8678
For designation
(20E6H)
(21E6H)
of
programmable
controller CPU
monitoring
function
8423
8679
(20E7H)
(21E7H)
8424
8680
(20E8H)
(21E8H)
APPENDICES APPENDIX
512
Appendix 3 Buffer Memory
Name
1st block monitoring device
Monitoring condition value designation
• At bit device
0: OFF 1: ON
• At word device
0 to FFFFH: Monitoring condition value
1st block monitoring device
Send pointer designation
(for condition match send and nonprocedural
data transmission)
0: No designation
1 to 100: Output head point (send from the nth)
Send the user frames designated in the
following send frame number designation areas
from the designated pointer position.
(address: CH1 side = BAH to 11DH, CH2 side =
15AH to 1BDH)
1st block monitoring device
Output quantity designation
(for condition match send and nonprocedural
data transmission)
0: No designation
1 to 100: Output quantity
(Designate the number of frame to be
transmitted.)
1st block monitoring device
Data No. for connection designation
(for condition match send)
0: No designation
0BB8H to 0BD5H, 8001H to 801FH: Data No.
for connection
2nd to 10th block monitoring devices
The structure of each area is the same as the 1st block monitoring device area.
Page 519 Monitoring device areas for the programmable controller CPU monitoring
function
System area
CPU error monitoring designation
Send pointer designation
(for condition match send and nonprocedural
data transmission)
0: No designation
1 to 100: Output head point (send from the nth)
Send the user frames designated in the
following send frame number designation areas
from the designated pointer position.
CH1 side = BAH to 11DH
CH2 side = 15AH to 1BDH
CPU error monitoring designation
Output quantity designation
(for condition match send and nonprocedural
data transmission)
0: No designation
1 to 100: Output quantity (number of frame to
be transmitted)
CPU error monitoring designation
Data No. for connection designation
(for condition match send)
0: No designation
0BB8H to 0BD5H, 8001H to 801FH: Data No.
for connection
Defaul
Protocol
t value
MC
Non Bi
0
R
0
R
0
0
R
0
R
0
0
R
Reference
Pd
Page 138 Settings for
Using the
Programmable
Controller CPU
Monitoring Function
Page 138 Settings for
Using the
Programmable
Controller CPU
Monitoring Function

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents