 Data flow: Reverse direction
• "No Complement Calculation" is designated (1B0H in hexadecimal is 432 in decimal)
Code type
Data length
1 byte
ASCII hexadecimal
ASCII decimal
HEX
*1 Values in '( )' indicate ASCII code.
• "One's complement" is designated (One's complement for 0000 01B0H is FFFF FE4FH)
When "Code type" is "ASCII decimal", the lower one word is extracted and converted from hexadecimal to decimal. (FE4FH
in hexadecimal is 65103 in decimal.)
Code type
Data length
1 byte
ASCII hexadecimal
ASCII decimal
HEX
*1 Values in '( )' indicate ASCII code.
• "Two's complement" is designated (Two's complement for 0000 01B0H is FFFF FE50H)
When "Code type" is "ASCII decimal", the lower one word is extracted and converted from hexadecimal to decimal. (FE50H
in hexadecimal is 65104 in decimal.)
Code type
Data length
1 byte
ASCII hexadecimal
ASCII decimal
HEX
*1 Values in '( )' indicate ASCII code.
*1
2 bytes
"0B" (30H 42H)
"23" (32H 33H)
B001H
*1
2 bytes
"F4" (46H 34H)
"30" (33H 30H)
4FFEH
*1
2 bytes
"05" (30H 35H)
"40" (34H 30H)
50FEH
Appendix 5 Operation Image and Data Structure of Predefined Protocol
3 bytes
4 bytes
"0B1" (30H 42H 31H)
"0B10" (30H 42H 31H 30H)
"234" (32H 33H 34H)
"2340" (32H 33H 34H 30H)
B00100H
B0010000H
3 bytes
4 bytes
"F4E" (46H 34H 45H)
"F4EF" (46H 34H 45H 46H)
"301" (33H 30H 31H)
"3015" (33H 30H 31H 35H)
4FFEFFH
4FFEFFFFH
3 bytes
4 bytes
"05E" (30H 35H 45H)
"05EF" (30H 35H 45H 46H)
"401" (34H 30H 31H)
"4015" (34H 30H34H 35H)
50FEFFH
50FEFFFFH
APPENDICES APPENDIX