Configuring
7.4 Display in the TIA Portal
Network view
The network view displays the two components of the SIMATIC Drive Controller, for
example:
● PLC_1 [CPU 150xD TF] and
● Integrated_1 [S120, CPU 150xD]
Different content is shown in the Inspector window depending on the selection in the network
view:
● Select an interface
● Select the CPU
● Select the SINAMICS Integrated
frame settings)
● Select the PROFIdrive Integrated subnet
the MC Servo clock) or couple the SINAMICS Integrated with another clock system (X142
technology I/Os or PROFINET interface X150).
You can copy/add/delete the components of the SIMATIC Drive Controller individually or
together. If you subsequently configure a SINAMICS Integrated, you need to assign the
SINAMICS Integrated manually to the master system to establish the PROFIdrive Integrated
connection.
Figure 7-5
Topology view
As the topology view is irrelevant for the SINAMICS Integrated, only the CPU of the
SIMATIC Drive Controller is displayed.
100
①
to configure it
②
to make CPU settings
Display in the TIA Portal – network view
③
to make SINAMICS Integrated settings (for example
④
to set the bus cycle time (and thus indirectly
System Manual, 11/2019, A5E46600094-AA