F2051 No Sequential Block In Target Position Preset Memory - Bosch Rexroth IndraDrive Troubleshooting Manual

Hide thumbs Also See for Rexroth IndraDrive:
Table of Contents

Advertisement

Rexroth IndraDrive

F2051 No sequential block in target position preset memory

Cause
When target position of a sequential block has been
reached, there is no new positioning block in target
position preset memory
Positioning block mode by mistake set to "sequential
block without intermediate stop"
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Supported by Firmware Variant:
In the case of the positioning block mode "sequential block without
intermediate stop" the drive is monitoring whether a new positioning block
is available in the target position preset memory when the target position
has been reached.
Remedy
Preset sequential block in time (before target position
has been reached)
Check positioning block mode and switch off sequential
block processing, if necessary (S-0-0346, Positioning
control word)
See also Functional Description "Drive-Controlled Positioning"
See also Functional Description "Positioning Block Mode"