8-42
Warning Diagnostic Messages (Exxxx)
E2814 Undervoltage in mains
Cause
Mains voltage falls under load
Mains voltage too low at power on
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Supported by Firmware Variant:
Supported by Supply Unit:
Note:
This warning only occurs for drive controllers of the HCS03
type!
The crest value of the mains voltage during operation has fallen below the
parameterized threshold value. The threshold value can be individually set
by the user via P-0-0810, Minimum mains crest value.
Remedy
Check dimensioning of mains connection, increase feed
wire cross section or use matching transformer, if
necessary
Use matching transformer
See also Functional Description "Power Supply"
E2814 - Attributes
Display:
E2814
Mess. no.:
E2814 (hex)
Rexroth IndraDrive
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
HMV01