C1219 Automatic commutation: overcurrent

C1220 Automatic commutation: timeout

DOK-INDRV*-GEN-**VRS**-WA01-EN-P
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Supported by Firmware Variant:
During the execution of the command for commutation offset
determination (C1200) an error was detected.
Cause:
The actual current is higher than the allowed maximum current.
Remedy:
Reduce the signal voltage (P-0-0506, Voltage amplitude for angle
acquisition) or increase the signal frequency (P-0-0507, Test frequency
for angle acquisition).
- or -
With P-0-0506 = 0 start the automatic determination of appropriate
values.
C1219 - Attributes
Display:
C1219
Mess. no.:
C1219 (hex)
Supported by Firmware Variant:
During the execution of the command for commutation offset
determination (C1200) an error was detected.
Cause:
An error occurred in the signal generator.
Remedy:
Switch the drive off and on again. If the error continues to be signaled,
contact the service department.
C1220 - Attributes
Display:
C1220
Mess. no.:
C1220 (hex)