9-102
Command Diagnostic Messages

C2402 Error when saving parameters

LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Supported by Firmware Variant:
During the execution of the S-0-0293, C2400 Selectively backup
working memory procedure command an error occurred.
Cause:
It was impossible to address the active, non-volatile memory (internal
flash memory or MMC, if plugged in) without error.
Remedy:
• Start the S-0-0293, C2400 Selectively backup working memory
procedure command again. If the error occurs again, then
• replace MMC (if plugged in) if necessary, then start the command
again. If the error occurs again,
• contact the service department.
C2402 - Attributes
Display:
C2402
Mess. no.:
C2402 (hex)
Rexroth IndraDrive
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
DOK-INDRV*-GEN-**VRS**-WA01-EN-P