6.7.2.2

Connecting the cables

Connect the cables to their corresponding busbars:
• Transformer cables to the busbars inside the primary
PCU (Fig. 6-15)
• Motor cables to the busbars inside the COU (Fig. 6-16)
• Ground cable to the PE ground busbar
6.7.2.2.1 Transformer cables
2
1
3
Figure 6-15 PCU cable terminals, top and bottom entry (back view)
(1) Busbars for transformer cables
(2) Top cable entry
3BHS799208 E01 REV E
2
3
ACS5000 WATER-COOLED USER MANUAL
06 ELECTRICAL INSTALLATION
2
1
3
(3) Bottom cable entry