19.5

VxWorks Image File Check

Before debugging the user program, ensure that a VxWorks image file of the same version as the C Controller module
is specified in CW Workbench.
Specifying a different file prevents normal debugging.
Development environment (personal computer)
(1) Checking method
Ensure that the serial number and the function version are the same as described below.
(a) C controller module
Check the 5-digit serial number and function version by using Setting/monitoring tools for the C Controller
module, or on the faceplate on the side of the C Controller module. For details, refer to the following.
Page 488, Appendix 9
(b) Development environment (personal computer)
Check by the VxWorks image file names specified by CW Workbench.
<Q24DHCCPU-V>
Q24DHCCPU-V_XXXXX-Y
<Q12DCCPU-V>
Q12DCCPU-V_XXXXX-Y_ModeEX
(2) When VxWorks image files are not identical
Acquire and use the VxWorks image files from the C Controller module.
1.
Use FTP to copy the VxWorks image files stored in the C Controller module's system ROM (/
SYSTEMROM/OS_IMAGEFILE) to the development environment (personal computer).
2.
Configure target server connection settings by CW Workbench.
For details, refer to the following.
CW Workbench Operating Manual
Must
match !
VxWorks
image
file
Function version
Serial number (first five digits)
Function version
Serial number (first five digits)
VxWorks
image
file
C Controller module
<Q24DHCCPU-VG>
Q24DHCCPU-VG_XXXXX-Y
CHAPTER 19 PROGRAMMING
Function version
Serial number (first five digits)
343