Hitachi FL.NET User Manual page 113

Option for s10v
Hide thumbs Also See for FL.NET:
Table of Contents

Advertisement

5 USER GUIDE
Network parameter read request: parard( )
[Linking procedure]
Struct parar_p {
long node ;
unsigned short *Erradr ;
unsigned char *Setadr ;
} ;
long (*parard)( ) ;
long rtn ;
struct parar_p *padr ;
parard = (long(*)( ))0xD60060 ;/* S10V */
rtn = (*parard)(padr) ;
[Parameters for mathematical/logical function]
[Parameters]
padr
Struct parar_p {
unsigned short *Erradr ;
unsigned char *Setadr ;
} ;
Be sure to specify an even-numbered address in padr.
Main
+0x0000
Message transmission service number (5)
+0x0004
Remote node number (1 to 254)
+0x0008
Error code storage address
+0x000C
Read parameter data storage address
long node ;
C language
Struct parar_p {
long node ;
unsigned short *Erradr ;
unsigned char *Setadr ;
} ;
long (*parard)( ) ;
long rtn ;
struct parar_p *padr ;
parard = (long(*)( ))0xDE0060 ;/* S10V */
rtn = (*parard)(padr) ;
: Input parameter storage starting address
: Remote node number (1 to 254)
: Error code storage address
: Read parameter data storage address