5 USER GUIDE
[Program structure]
The program structure is shown below. With the module having the node number 1
(FL.NET module for LPU01) and the module having the node number 2 (FL.NET module
for LPU02) interconnected, cyclic transfer operations are performed between the FL.NET
modules. (The FL.NET modules perform cyclic transfer operations. The user does not
have to pay attention to the operations.)
When R0A0 startup is detected in LPU01 side ladder program subsequently, the node 1
module transmits a 1,024-byte transparent message (TCD number = 11000) to the node 2
module. The node 2 module receives the transparent message from node 1 module.
This program example is a ladder program, which runs in this manner.
When using this ladder program, be sure to place the S10V in the RUN state.
Ladder program
Transparent
transmission
buffer
FL.NET (node 1)
module
Mathematical/logical
function
Item
Function
Send buffer
Receive buffer
Mathematical/logical function
LPU01
Node 1
Node 2
transmission
reception
area
area
Cyclic transfer
Message transfer
LPU
Transmits transparent messages.
Address
FW000 to FW1FF
Number of bytes
1,024 bytes
Address
Number of bytes
FLCM
0xD60000
Node 1
reception
area
LPU01
⎯⎯
⎯⎯
5-100
LPU02
Ladder program
Node 2
Transparent
transmission
reception
area
buffer
FL.NET (node 2)
module
Mathematical/logical
function
LPU02
Receives transparent messages.
⎯⎯
⎯⎯
FW000 to FW203
1,024 bytes + 4 words
0xD60000