[LPU01 side ladder program]
V000
R0A0
(00001)
When the R0A0 turns ON, the program runs and checks the network participation status
bit (R088) and user-requested-processing-in-progress bit (R080) in the self-node status
flag (message processing can be performed when the network participation status bit is set
with the user-requested-processing-in-progress bit reset.)
The parameters for transparent-message transmission are specified by
mathematical/logical functions.
MOV 18 = FL400
The message transmission service number is set to 18. A transparent-message
transmission request is specified.
MOV 2 = FL402
The remote station (LPU02) is specified.
AST RW090 = FL404
The error code storage address (RW090 real address) is specified.
AST FW000 = FL406
The transmission buffer address (FW000 real address) is specified.
MOV 1024 = FL408
The transmission word count is specified.
R088
R080
5-101
5 USER GUIDE
MOV
18 = FL400
F
MOV
2 = FL402
F
AST
RW090 = FL404
F
AST
FW000 = FL406
F
MOV
1024 = FL408
F
MOV
11000 = FL40A
F
FLCM
FW400
F