[Parameters]
padr
Struct Reqmacro_p {
long node ;
unsigned short *Erradr ;
unsigned long *Retdadr ;
long ParaCnt ;
unsigned long Para[3] ;
} ;
Be sure to specify an even-numbered address in padr.
Parameter
Message transmission service
number
Remote node number
Error code storage address
CPMS macro execution result
storage address
CPMS macro parameter count
CPMS macro parameter
(*) For the relationship between real address on LPU (memory address) and symbol
name such as XW000, see "Table 2-5 Virtual Address Spare and Symbol
Names." "Memory address" in table is the address to be specified.
[Return code] (for C mode handler only)
0 (0x00000000): Normal termination
-1 (0xFFFFFFFF): Parameter abnormality exists or the handler is busy processing another
message. Error code is stored in area which specified error code storage
address. For content and measure of error code, see "Table 7-3 List of
Detectable Codes."
-2 (0xFFFFFFFE): Specifies real address (0x01000000 to 0xFFFFFFFE) on CMU at error
code storage address or CPMS macro execution result storage address.
Please review the specified address.
: Input parameter storage starting address
: Remote node number (1 to 254)
: Error code storage address
: CPMS macro execution result storage address
: CPMS macro parameter count
: CPMS macro parameter
Input range
13 (only when a mathematical/logical function
is used)
1 to 254
Specify a real address (even-numbered
address) on the LPU. (*)
See [Function]
5-77